Mounting of ignition electrode
· Place tip of ignition electrode between clip and bracket.
· Push ignition electrode upwards.
· Position electrode tip in the hole on the top of the bracket.
· Push ignition electrode further upwards until the thickning passes
the hook of the bracket.
· Check spark gap to target. Spark gap must be between 2.5 and
3.5 mm.

Who we are

Products

Home

Combustion Research Centre

Contact

Where we are

Customer supporto

Via Lago di Misurina, 76 - Z.I. - 36015 SCHIO-Italy - Tel. +39(0)445/678678 - Fax +39(0)445/678679 -

E-mail: polidoro@polidoro.com

Designed by AccaPi Studio S.r.l.

· Description
· Pilot burner overview
· Interactive choice
· Series
· Q 334A 2000
· Q 385A 2000
· Q 349A

Q 334A 2000
Installation

· Q 359A
· Q 358B
· Application
· Aeration
· Pilot flame ignition
logo_polidoro_new
IMPORTANT
Installer must be a trained, experienced service person.
Turn off gas supply before starting installation.
An important requirement for the Q334A is that it must be installed
correctly.
Consult Honeywell application engineers when considering using
these devices.

Locating pilot burner
· Position for easy access and observation.
· Position so that pilot flame will not touch adjacent parts or main
burner flames.
· Position so that pilot flame will ignite main burner when pilot gas
pressure just exceeds safety shut--off value.
· Ensure that pilot flame has an ample supply of dust free air.
· Do not expose to draughts which will extinguish pilot flame or
deflect it from the flame sensingelectrode/thermocouple.
· Pilot burner should not extinguish when main burner is switched
"ON" and "OFF"'.
· Pilot burner shall be mounted in a preferably upright position.

Pilot gas connection
· Square off end of tubing, clean, remove burrs and form it.
· With orifice assembly and compression fitting in position, insert
tubing into target spud until it bottoms and turn compression fitting
finger tight.
· Hold tubing to prevent turning and tighten compression fitting with
a wrench about two turns beyond finger tight for 6 mm tubing and
about 3/4 turn beyond finger tight for 4 mm tubing to make a
pressure tight joint.

Features
Selection chart
EN2R-9002 0109R6-NE
Order info
Specifications
Performance
Drawing
Installation
CAUTION
Do not use jointing compound.
Do not bend tubing near fitting after tightening as this may
result in gas leakage at connection.

Electrical connections

Pilot gas
connection

CAUTION
Switch off power supply before making electrical connections.
Wiring must be within local regulations.
Follow the instructions supplied by the appliance manufacturer.

Mounting of thermocouple
Insert thermocouple tip into thermocouple spud of pilot burner and tighten with the attached nut.

Mounting of sensing electrode
Insert flame sensing electrode into thermocouple spud of pilot burner and fix with gland.