Premix pilot burner
(primary aerated)

· Q 359A
· Q 358B
· Application
· Aeration
· Pilot flame ignition
logo_polidoro_new
· Target pilot burner
· Premix pilot burner
AERATION
A premix pilot burner is primary aerated. An air inlet is built into the pilot tube, just after the
gas injector but outside the burner chamber. Primary air is drawn from outside the combustion
chamber by the gas, ensuring a premixed gas/air mixture.
Generally, secondary air is available inside the chamber, but in modern burners it can be very
low if the combustion chamber is sealed (only primary air thru the main burner and thru pilot
burner is available). Premix pilot burners are suitable for burners with high or only primary
aeration (no secondary air); they are gerally modern atmospheric low NO x premix burners,
with sealed combustion chambers.
Premix pilot burner application with low NOx
atmospheric burner

(the combustion chamber is almost close or even
sealed,that means low or no secondary air)
EN2R--9002 0109R6--NE